Rs232 Data Capture Program
Reading Weight from Ohaus Balance via RS2. Download Software. Data Acquisition Technical Support Logging from Ohaus Balance. Capturing Data from an Ohaus Balance. Free Com. Debug software logs data from Ohaus balances, and other instruments with an RS2. PC running Windows. All data is time stamped and can be imported into Excel. To download Com. Debug just subscribe to our monthly Monitor newsletter ISSN 1. Com. Debug lets you log data from one instrument and save it in a text file. For data logging from many instruments, charting and real time data capture by Excel our. Windmill data acquisition software is just 5. To use Windmill to capture data from a Ohaus balance download the software then. Run the Windmill Com. Debug, select Create a new Windmill Instrument File, and enter your balances communication settings. Run the Windmill DDE Panel, Logger or Chart program to save or display data from your balance. After you have entered your configuration settings with Com. Debug, you dont need to use this again and can go straight to the logging and display programs. Data acquisition DAQ is the measurement, recording, analyzing, and presentation of real world phenomena. It includes electrical measurements such as voltage. Windmill continually captures data from Ohaus Balances. Using Com. Debug to Enter Data about Your Ohaus Balance. For an overview of entering the configuration settings see the Getting Started with COMIML and Com. UT8RlGBXglXXXagOFbXy/112433227/UT8RlGBXglXXXagOFbXy.jpg' alt='Rs232 Data Capture Program' title='Rs232 Data Capture Program' />Debug page. Specific example settings for an Ohaus Pioneer FX3. Ranger 3. 00. 0 series are given below. The opening screen. Rs232 Data Capture Program' title='Rs232 Data Capture Program' />The first time you use Com. Debug select Create a New Windmill Instrument File. Subsequently, when you have saved settings, select Edit an Existing Windmill Instrument File. COM Port Settings. These must be the same as your balance uses. Check the Instruction Manual and see the RS2. Comm Port Select the port to which your instrument is connected. Baud Rate Can be 6. PBX Data Logger enables users to record, track and archive phone calls and can capture SMDR or CIR data from RS232, RS845, TCP or UDP ports, custom processes it to. RS2. 32 menu or for the Ranger 3. COM1 menu. Default is 9. Data Bits 7 or 8 check with the balances Parity setting on the RS2. Ranger 3. 00. 0 series, the COM1 menu. Default is 8. Parity In Com. Debug choose odd or even check which using the balances RS2. Parity setting or for the Ranger 3. COM1 menu. Default is none Flow control Choose none, but make sure this is also selected at balances RS2. Ranger 3. 00. 0 series, the COM1 menu. Default is none Choose Serial or Edit COM Port Settings to bring up this dialogue. Fill in your settings then click OKData Format. Choose Edit Message1 from the Main Menu to bring up Com. Debugs Message Screen. Enter a command or prompt string to send to the balance to ask for data. Click the Send button, and the instrument should send a reply see Trouble Shooting below if not. Now click the Parse button and enter instructions to extract the data from the balances reply. Check your balances Manual for details of the commands to send, and the format of the balances reply. The example given below requests the stable weight. Use the non print menu to enter the carriage return lt CR and linefeed lt LF. Example prompt command Plt CR lt LF P is upper case. Data format ASCIIExample parsing Ignore Until 0. Extract Until space. Instrument Timing. In the Main Menu choose Edit the Instrument Timings and enter these settings. Read Directly. Timeout 5. Instrument Idle or Wait Time 0. Data Persistence Time 5. Collecting Readings. In the Message Screen click Run to check that everything is working then select the File menu to save readings in a text file. Gta Iv Pc Fix. Save your settings from the Main Menu select Save. IMD file. Further Information COM Port Settings. Pioneer Balances Instruction Manual. Ohaus Ranger 3. 00. Manual. Using Windmill Logger to Capture Data. The free Com. Debug program might be all you need. However, if you want to connect more instruments, chart data, send data to Excel in real time and so on, you can use the other Windmill programs. Run Windmill Setup. IML to specify alarms, convert engineering units, etc. You can then collect and display data with Logger, Chart and DDE Panel. From DDE Panels File menu select Load Hardware Setup and choose the. Connect your weight channel. You should see the correct weight in DDE Panel. Proceed similarly for the Logger and Chart programs. Getting the data into Excel. You can use the Windmill Logger or Com. Debug program to collect data, and after collection has finished import it into Excel. Alternatively, you can collect data with Excel in real time by using an Excel macro to read data from the Windmill DDE Panel or RTD server. Trouble Shooting. If you are unable to get data from your balance go back to Com. Debugs Terminal or Message screen. Make sure your command is shown in the prompt grid. Click the Send button does your instrument replyIf you only see your command being sent, and no data. Make sure that the balance is switched on and plugged into the PCs com RS2. Check that the communication settings you entered in Com. Debug match those currently in use by the balance COM port, baud rate, parity, etc. If using a USB RS2. USB Serial page for details, especially point 7. If still no luck see our Testing Serial Port Communication page. If, in Com. Debug you see data coming in but DDE Panel isnt showing it, you may need to edit your parsing settings. Go to Com. Debugs Terminal or Message Screen, click the Parse button. Enter your Ignore and Extract Settings and click the Step menu. Is your data shown in the Value column If not adjust your settings. If you are getting accurate data readings, but much slower than expected, change your sampling rate. With COMIML, Windmill can make 5 readings per second per channel. So it can record one weight measurement every 0. If you have the sampling interval set much smaller than this, then Windmill may slow down considerably and only make a couple of readings per minute. Success Have you successfully used Windmill with your balance Let us know about your project. If you have any problems fill in the form on our technical support page.